An engine can lose fuel flow while the airplane still carries plenty of fuel. A restricted vent can let tank pressure fall as fuel leaves. A pump can make pressure at idle but fail to deliver enough volume for takeoff. A quantity indicator can show fuel in a tank that has no working feed path to the engine. Each problem looks different on the schematic, even though all three can end with the same loss of power.
This guide follows Chapter 14 of the FAA’s Aviation Maintenance Technician Handbook – Airframe, FAA-H-8083-31B. It covers the airframe side of the system, from storing and servicing fuel to delivering it to the engine. For work on a specific aircraft, use its current maintenance instructions, applicable airworthiness directives, and airworthiness limitations. Fuel grades, leak limits, test setups, and allowable configurations depend on the aircraft and its installed equipment.
1. What the fuel system has to do
A fuel system stores the approved fuel and supplies each engine with the required flow at an acceptable inlet pressure. It has to do that throughout the aircraft’s approved operating envelope. Tank quantity, aircraft attitude, fuel temperature, altitude, and engine demand all affect the conditions at the inlet.
A useful way to read a fuel schematic is to trace three paths separately. Follow the fuel path from the pickup to the engine. Follow the air path through the tank vents. Then follow the control and indication paths between switches, sensors, valves, pumps, and displays. A fuel-flow problem can start in any of the three.
| Design concern | How the system addresses it | What can go wrong |
|---|---|---|
| Flow at high engine demand | The design provides enough delivery capacity under the applicable test conditions | An engine can idle normally with a restriction that limits takeoff flow |
| Reliable pickup | Sumps, collectors, baffles, and suitable pickup locations keep fuel available as it moves in the tank | A pickup can uncover during a maneuver with low fuel quantity |
| Pressure control | Tank vents, pumps, and regulating or relief devices keep pressures within their intended ranges | A plugged vent can starve the engine or load the tank structure |
| Engine feed independence | Separate feed sources or paths reduce exposure to a single failure | A common valve, manifold, electrical source, or contamination event can affect multiple engines |
| Ignition protection | Bonding, wiring protection, and qualified components control potential ignition sources | Incorrect hardware or wiring routing can defeat a design feature that is hard to see during a functional check |
| Serviceability | Drains, access panels, connectors, and test points support inspection and maintenance | Poor access or a drain that fails to sample a low point can hide contamination |
Usable fuel and fuel flow
Usable fuel is the portion available under the conditions established for the aircraft. Unusable fuel is the portion that the design cannot reliably deliver under the applicable conditions. Fuel can remain in a tank’s corners, below a pickup, or in parts of the system with no effective flow to the engine.
Flow and pressure measure different things. Pressure is force per unit area at a point. Flow is the amount of fuel passing a point per unit time. A pressure gauge showing a normal value with little demand tells you little about the volume available at high demand. A valid flow check uses the aircraft’s specified configuration, test point, and acceptance limits. Some legacy certification rules also distinguish the required margins for gravity-fed and pump-fed systems, so a handbook percentage should never become a generic field test criterion.
Venting, expansion, and lightning protection
Fuel leaving a tank must be replaced by air or another approved venting arrangement. During filling, air must also have a way out. A vent line may include a high point, a drain, a check valve, or connections to a surge tank. Designers account for pitch and roll, thermal expansion, and the possibility that fuel can enter the vent system.
A tank also needs room for the fuel to expand as it warms. The air and vapor space above the liquid is called the ullage. On aircraft with fuel-tank inerting, the system reduces the oxygen concentration in the ullage to reduce flammability. Ignition-source controls are still part of the design.
Fuel tank lightning protection can depend on the electrical continuity of joints, approved fastener details, bonding paths, and the routing of wiring near the tank. An acceptable pump run or quantity indication gives no evidence that a disturbed bonding path meets its lightning-protection requirement.
2. Aviation fuels and the problems they can cause
| Fuel | Typical application | Properties to keep straight |
|---|---|---|
| AVGAS 100LL | Spark-ignition piston engines approved for that grade | Blue aviation gasoline with tetraethyl lead. The LL designation stands for low lead relative to certain older avgas grades |
| Approved unleaded avgas | Aircraft and engines approved for the particular grade | Verify eligibility for the specific installation and check applicable approval conditions |
| Jet A | Turbine aircraft and certain approved compression-ignition aircraft engines | Kerosene-type fuel with a specification maximum freezing point of −40 °C |
| Jet A-1 | Widely used in international turbine operations | Kerosene-type fuel with a specification maximum freezing point of −47 °C |
| Jet B | Some approved operations where cold-weather properties matter | Wide-cut fuel with higher volatility than kerosene-type jet fuel. Use depends on aircraft approval and supply |
Fuel color can help identify a discrepancy, but a convincing color does not establish grade or purity. Jet fuel can be clear to pale straw, and a mixture of jet fuel and avgas may retain enough dye to appear plausible. Verify the grade against the aircraft placards, operating data, and servicing records. Nozzle and filler geometry can reduce misfueling risk where installed.
Volatility, vapor lock, and carburetor icing
Volatility describes a fuel’s tendency to evaporate. Avgas must vaporize well enough to support starting and mixture preparation, including when cold. It must also remain liquid in the part of the delivery system designed to carry liquid fuel.
Vapor lock develops when vapor forms where a pump or metering system needs a continuous liquid supply. Heat, lower ambient pressure, and reduced pressure at a pump inlet all favor vapor formation. A suction-side restriction lowers local pressure further. Putting a boost pump near the tank can raise pressure in the downstream feed line and make vapor formation less likely, depending on the installation.
Carburetor icing occurs in the induction system. Air accelerates through the carburetor and experiences a pressure drop, and evaporating fuel absorbs heat. Together these effects can cool the air enough for moisture to freeze in or around the venturi and throttle area, even with outside air above freezing. Ice at the carburetor restricts induction airflow. Ice at a fuel filter or pickup restricts liquid fuel delivery. The location dictates how the aircraft’s ice protection addresses the problem.
Detonation, preignition, and fuel ratings
Detonation is spontaneous combustion of the remaining unburned mixture after normal ignition has started. The sudden pressure rise can overheat and damage cylinders, pistons, and other parts. Inadequate fuel knock resistance is one possible contributor.
Preignition starts before the normal spark event. A hot deposit, overheated plug, or another hot surface can ignite the charge early. Surface ignition describes ignition from a hot surface and can occur at other times as well. Detonation and preignition are distinct processes that can aggravate each other.
Avgas grades describe knock resistance under defined test conditions. Historical dual ratings distinguish lean-mixture and rich-mixture performance. Octane number and performance number come from test reference scales, so the number does not directly describe the fuel’s energy content. Fuel chemistry also matters to the airframe. Aromatic compounds can affect some elastomers and seals, making material compatibility and approved fuel selection part of the same maintenance problem.
Turbine fuel, heat, and water
Kerosene-type turbine fuel is less volatile than avgas. It can also serve as a heat sink, for example in a fuel-oil heat exchanger. On a cold-soaked aircraft, trace water can precipitate from solution as fuel cools and later freeze. Water ice can obstruct screens, filters, or other small passages before the bulk fuel reaches its own freezing point.
A fuel-oil heat exchanger transfers heat from oil to fuel. The same unit may therefore cool the oil and warm the fuel. Other designs use different means of fuel heating or filtration. The manufacturer specifies allowable fuel temperatures and any approved fuel-system icing inhibitor. Additive approval, dosage, and handling are installation-specific.
3. Fuel system layouts by aircraft type
The following paths are examples. The installed schematic controls the location and sequence of components.
| Aircraft or system | Typical feed arrangement | Maintenance distinction |
|---|---|---|
| High-wing piston, gravity feed | Wing tanks feed a carburetor through a selector or shutoff and a strainer | Liquid head depends on the elevation difference between the tank fuel level and the inlet |
| Low-wing piston, pump feed | A selected tank supplies the engine-driven pump, often with an electric auxiliary pump in the circuit | Pump inlet conditions and fuel selector position matter, especially when fuel levels are low |
| High-wing piston, fuel injection | Gravity may feed a reservoir or supply line, with pumps furnishing pressure for the injection system | Wing height alone does not establish adequate metering pressure |
| Light piston twin | Each engine normally has an assigned feed source, with crossfeed on some installations | Auxiliary tanks may feed an engine directly or transfer to a main tank, depending on design |
| Large reciprocating aircraft | Multiple tanks, selectors, boost pumps, and crossfeed plumbing support the engines | Tank-use sequence and valve position can change the effective feed path |
| Jet transport | Wing and center tanks may feed a manifold through pumps and valves, with separate transfer or scavenge arrangements | Engine feed, refuel, transfer, and jettison can use different paths through the system |
| Helicopter | One or more cells supply a pickup, reservoir, or collector, often with boost pumps or transfer equipment | Cell interconnects, vent routing, and crash-resistant components are installation-specific |
Gravity feed and pump feed
A simple carbureted high-wing system can use the height of the fuel above the carburetor to generate head pressure. The available pressure margin decreases with lower fuel level or an unfavorable attitude, and every line, fitting, and screen adds resistance. Both the vent and the fuel pickup must work for the arrangement to deliver properly.
A pump-fed piston installation usually has an engine-driven pump and may have an electrically driven auxiliary pump. The auxiliary pump’s job can include priming, supplementing pressure, or providing an alternate source if the engine-driven pump fails. The aircraft’s operating instructions determine when to use it. Some plumbing includes a bypass path for flow through or around an inactive pump.
Crossfeed, transfer, and scavenge
Crossfeed lets an engine receive fuel from an alternate feed source through interconnected plumbing. Transfer moves fuel from one tank or compartment to another. Scavenge recovers fuel pooled away from the normal pickup, often moving it to a collector or another tank.
For example, opening a light twin’s crossfeed valve may allow the right engine to draw from the left tank. Fuel can leave the left tank and go straight to the right engine. Moving the same fuel into the right tank would require a transfer path. In a transport aircraft, a center tank might feed engines directly or transfer fuel to wing tanks, depending on design. The fuel system schematic and its normal operating sequence explain what a quantity change should look like.
Transport systems and rotorcraft details
In a transport aircraft, boost pumps often pressurize engine-feed manifolds. Check valves isolate branches from reverse flow. Shutoff valves isolate engines or other consumers, including an APU on some aircraft. A refuel manifold may distribute incoming fuel to several tanks via individual refuel valves and high-level shutoff devices. Aircraft with jettison capability have design-specific controls and discharge paths. The system’s availability, restrictions, and intended retained fuel quantity are aircraft-specific.
Helicopter fuel cells may connect to a common collector or use pumps to transfer fuel between compartments. A crash-resistant installation can include flexible crash-resistant cells, mountings designed for impact loads, and self-sealing breakaway fittings. Those features function as a system. Replacing a hose or fitting by dimensions alone can change how the installation behaves under impact.
4. Tanks, lines, and valves
| Tank construction | How it stores fuel | Areas that deserve attention |
|---|---|---|
| Rigid removable | A separate metal or other rigid container sits in a supporting structure | Seams, fittings, supports, pads, attachments, and evidence of fretting or corrosion |
| Bladder | A flexible fuel cell fits into a structural cavity and is retained by attachments | Folds, chafing, loose attachments, damaged cavity protection, and trapped water |
| Integral or wet wing | Sealed aircraft structure forms the fuel tank | Sealant at fasteners and joints, access covers, structural damage, and internal leaks into adjacent bays |
Baffles limit rapid movement of fuel and can help maintain supply near a pickup. Some baffles or collector partitions use flapper valves to admit fuel in one direction. A low point can collect water and debris, which is why a tank may have more than one drain. The position of a drain relative to the aircraft’s servicing attitude matters when interpreting a sample.
Rigid tubing and flexible hose may both appear in a single installation. Flexible connections accommodate movement, vibration, or removable equipment. Inspect for damaged supports, contact with nearby structure, bends, deterioration, or evidence of leakage. In a suction line, a poor connection may admit air during operation without leaving an obvious wet spot when the system is stopped.
| Valve or device | Purpose | Typical diagnostic distinction |
|---|---|---|
| Selector | Chooses a source or operating position | The handle can appear in position while the valve or linkage is misrigged |
| Shutoff | Isolates a tank, engine, or branch | A command or switch position alone cannot confirm the valve has traveled |
| Check valve | Permits flow in one direction | Reverse leakage can let pressure decay or feed the wrong branch |
| Crossfeed valve | Connects otherwise separate feed paths | Its position changes which sources can supply a consumer |
| Refuel valve | Admits fuel to a tank from the refuel manifold | Failure to open affects filling. Failure to close can cause overfill |
| Relief or bypass valve | Opens an alternate path at a defined condition | Operation may preserve flow while changing protection or indication |
| Drain valve | Allows sampling or removal of fuel and accumulated contaminants | A stuck or leaking drain can admit contamination or lose fuel |
Cone and poppet arrangements can be used in selector or shutoff designs. Gate valves can isolate larger passages. Motor-operated valves commonly use position feedback or limit switches. Solenoid valves use an energized coil to move an internal element, with normal and failed positions set by the particular design. Separate the electrical command, actuator motion, position feedback, and actual hydraulic condition when diagnosing a valve.
5. Fuel pumps, filtration, and ice protection
| Pump type | Operating principle | Common system role |
|---|---|---|
| Centrifugal boost pump | An impeller accelerates fuel and the pump housing converts some velocity into pressure | Tank or manifold feed, transfer, and positive pressure at the engine pump inlet |
| Vane pump | A rotating element and sliding vanes move a volume of fuel through changing chambers | Engine-driven pressure supply in some installations |
| Pulsating electric pump | Repeated movement of a diaphragm or plunger draws and discharges fuel through check valves | Auxiliary or priming service on some light aircraft |
| Ejector or jet pump | Pressurized motive fuel accelerates through a nozzle and entrains surrounding fuel | Scavenge, transfer, or collector feed without a rotating element at the pickup |
| Hand pump | Manual motion displaces fuel through check valves | Priming or auxiliary service where fitted |
An ejector depends on the source of its motive flow. A blocked motive nozzle or a weak supply can stop transfer even when the pickup and discharge lines are clear. Before suspecting a mechanical pump that the schematic does not show, identify the branch that provides motive fuel.
A vane pump moves fuel by displacement and may have a relief or regulating arrangement. A centrifugal pump has a different pressure-flow characteristic and can lose performance if its inlet is uncovered or contains vapor. On either design, motor noise and current draw are supporting observations. Confirm output through the specified checks.
Pickup screens catch larger debris. A strainer or gascolator may provide a low point for water and sediment. Finer filters protect close-tolerance downstream equipment. Filters on some installations have differential-pressure indication or a bypass. Differential pressure is the pressure drop from the inlet side to the outlet side. A restriction increases that drop for a given flow. A bypass can restore a flow path around the filter element while allowing unfiltered fuel downstream.
Examine contamination found in a filter in context. Repeated debris following element replacement can point to a degrading hose, sealant, corrosion, contaminated servicing equipment, or a tank problem. Finding debris in an element tells you where it was caught. Its material, quantity, and recurrence help identify where it came from.
6. Quantity, flow, pressure, and warnings
| Indication | What it measures or reports | What to verify when the indication looks wrong |
|---|---|---|
| Fuel quantity | Fuel in a tank or cell, displayed in units appropriate to the installation | Aircraft attitude, sender or probe health, wiring, calibration, and independent quantity data where available |
| Fuel flow | Rate passing a transducer or a rate derived from another measured variable | Location of the measurement point, calibration, and whether the design accounts for return flow |
| Fuel used or remaining from a totalizer | Fuel consumed from integrated flow, with remaining fuel based on a starting quantity | The starting value and any subsequent refueling, leakage, or unmetered fuel movement |
| Fuel pressure | Pressure at a specified point | Gauge or sender accuracy, pump source, and demand under the test condition |
| Low-pressure warning | Pressure at a switch or sensor has crossed its warning threshold | Sensor location and logic, actual feed pressure, and pump or valve state |
| Fuel temperature | Temperature at a specific sensing location | Which tank or line is measured and which fuel grade and operating limit apply |
| Valve-in-transit light | Valve feedback is between the commanded end positions or disagrees with commanded state, depending on logic | Actuator operation, mechanical position, limit switches, and circuit continuity |
Float senders and capacitance probes
A float sender follows liquid height. A linkage can move a variable resistor or another sensing device. Tank shape determines how a change in level corresponds to a change in volume. A sticking float, worn sender, or poor electrical connection can make the gauge intermittent or inaccurate over part of its range.
A capacitance probe detects changes as fuel replaces air around the probe electrodes. Air and fuel have different dielectric properties. A system may use multiple probes to account for tank geometry and compensating elements to account for fuel properties. Probe wiring, connectors, contamination, and the processing unit all influence the displayed result. The approved test equipment and method matter when working around tank circuits.
Some aircraft provide an independent ground check through a dipstick, dripstick, or magnetic measuring device. These readings typically depend on attitude and on the aircraft’s conversion tables. On a transport, the indication commonly displays mass; a smaller aircraft may display volume. Two tanks holding equal volumes can hold different masses if fuel densities differ.
Flow and quantity can disagree for good reasons
Suppose a totalizer starts at 50 gallons and records 18 gallons consumed. It calculates 32 gallons remaining. If the aircraft actually started with 45 gallons, the same calculation overstates the remaining fuel by 5 gallons. A leak upstream of the transducer can also reduce onboard quantity without being counted as engine consumption. Comparing the tank indication, totalizer, servicing records, and expected burn helps distinguish a measurement issue from a real loss of fuel.
7. Troubleshooting feed, transfer, and indication faults
Start with the reported conditions. Record which engine or tank was affected, system configuration, quantity in each tank, engine demand, and whether the fault appeared after servicing or maintenance. On a larger aircraft, distinguish an engine-feed fault from a transfer failure or a refueling problem before deciding which schematic and test procedure apply.
| Observation | Possible causes | How to narrow the problem |
|---|---|---|
| Pressure looks normal at low demand and falls as flow rises | Restriction, weak pump, air entering the suction side, or poor venting | Use the approved flow and pressure checks at the specified points to distinguish delivery capacity from sensing error |
| Pressure improves with the auxiliary pump | Engine-driven pump weakness, an upstream restriction, vapor formation, or an installation-specific flow change | Trace the auxiliary pump’s location and bypass paths before attributing the result to the engine-driven pump |
| One tank fails to transfer | Pump, valve, check valve, motive supply, control logic, or an indication fault | Compare the commanded sequence with actual valve feedback, expected pressure, and independently verified quantity |
| Fuel quantity changes unexpectedly during flight | Normal feed sequencing, unintended crossflow, leakage, or indication error | Check whether changes agree with the commanded feed path and recorded consumption |
| Fuel odor or staining appears after refueling | Cap, vent overflow, access cover, filler connection, or tank seam | Identify the conditions that produce it and trace the first wet area along possible migration paths |
| Pressure or quantity indication is intermittent | Sensor, connector, wiring, power supply, or an actual intermittent system fault | Compare the indication with approved independent measurements before replacing a component |
A system that behaves normally with a full tank may show a fault near the bottom of the usable range. Less liquid head changes the inlet conditions. A defect above the low fuel level may also stop leaking once the fuel drops below it. Both are reasons to record the quantity and configuration that reproduce the symptom.
Locating and classifying leaks
Fuel can migrate along a seam, under a floor, or through an opening into another compartment. Airflow may spread a stain away from its source. Look for the highest or earliest evidence consistent with the aircraft’s attitude and the system being pressurized. A stained wing surface may point toward an access-cover seal, a fastener, a vent outlet, or a leak that began elsewhere. The location where the fuel emerges is one part of the diagnosis.
Handbook descriptions such as stain, seep, heavy seep, and running leak describe progressively more visible wetting or movement. Operational disposition depends on the aircraft’s approved criteria, including the location, spread over the specified observation period, and potential exposure to ignition sources or enclosed areas. The same apparent external wetting can have different consequences at a wingtip and near a hot surface.
A leaking fitting can result from a damaged flare, incorrect assembly, a damaged seal, or a tube under stress. Tightening alone can worsen the damage. Use the specified seal material, size, installation practice, and hardware. After a repair, check for leakage in the operating states called for by the maintenance data and restore the affected system’s rigging, support, bonding, and identification.
8. Tank repair and fuel tank safety
| Construction | Repair considerations |
|---|---|
| Welded rigid tank | Material compatibility, weld integrity, distortion, and the approved leak-test method matter. Hot work requires an approved process and controls for residual fuel vapor |
| Riveted rigid tank | Identify whether leakage originates at a rivet, seam, fitting, or crack. The repair may require both structural and sealing work |
| Soldered tank | Verify that the construction and material are eligible for the prescribed repair process |
| Bladder cell | Assess the cell and the supporting cavity. A repair will be short-lived if a rough surface, loose attachment, or fold keeps damaging the cell |
| Integral tank | Identify the leaking joint or fastener, evaluate the structure, and follow the specified sealant preparation, application, cure, and test requirements |
Integral tanks typically use sealant systems with defined preparation, application life, and cure conditions. A surface that looks clean can retain fuel, old sealant, or residues that interfere with adhesion. Sealant renewal and structural repair are separate determinations. When a crack, loose fastener, or corrosion is involved, fix the structural condition using applicable data before relying on a sealed surface.
Fuel tank entry and hot work require specialized controls. A drained tank can still contain ignitable vapors and can present oxygen and exposure hazards. The applicable maintenance and confined-space procedures govern isolation, ventilation, atmospheric monitoring, permitted equipment, and emergency arrangements. Keep the requirements for worker protection and the requirements for protecting the aircraft’s design features in view throughout the task.
Critical design configuration control limitations (CDCCLs) preserve specific design features that control ignition risks on applicable aircraft. Examples can involve separation between fuel quantity wiring and other electrical circuits, bonding details, or the approved configuration of a fuel pump. An apparently interchangeable part or a convenient wire reroute can change the protection the design depends on. Check the airworthiness limitations and instructions for continued airworthiness before disturbing these features.
9. Fuel contamination and sampling
| Contaminant | Where it can come from | Why it matters |
|---|---|---|
| Free water | Rain entry, contaminated delivery fuel, or water that separates as fuel cools | Pools at low points and can freeze or interrupt the supply of combustible fuel |
| Dissolved or suspended water | Fuel can hold dissolved water, and agitation can disperse droplets | Cooling can release dissolved water. Fine droplets can make a sample hazy |
| Solid particles | Dirt, corrosion products, degraded seals or hoses, tank sealant, or servicing equipment | Can load filters, obstruct passages, or damage close-clearance parts |
| Surfactants | Fuel handling, contamination, or carryover of surface-active chemicals | Can interfere with water separation and allow water to travel with fuel |
| Microorganisms | Growth where water and fuel coexist, commonly at their interface | Can produce sludge and contribute to corrosion or filter loading |
| Wrong fuel or foreign liquid | Misfueling, shared equipment, or cross-contamination | Can affect combustion, knock resistance, low-temperature performance, or material compatibility |
Free water generally settles below hydrocarbon fuel. A sample drawn entirely from a water layer can look clear, which is one reason clarity alone is insufficient. A separate water layer, droplets, haze, solids, or unusual odor requires evaluation under the applicable procedure. The specified drain points, aircraft attitude, and settling interval matter. A sample from one drain represents that sampling point under those conditions.
Contamination can recur after an otherwise clean-looking sample. A bladder fold can trap water away from a drain. A leaking cap can admit water only during rain or washing. Microbial contamination can show up as repeated filter loading or deposits even when a routine visual sample misses the affected area. Control the source as well as the contamination already present. Use approved detection methods and follow the maintenance instructions for any sampling, cleaning, or treatment.
Suspected misfueling calls for escalation under the operator’s procedures before engine operation. A fuel receipt, supplier records, samples, and the amount and type of fuel already aboard can help establish what happened. Corrective action depends on the installation and on where the suspect fuel may have traveled.
10. Refueling, defueling, and fire prevention
Overwing refueling adds fuel through a filler opening on an individual tank. Pressure refueling sends fuel into a manifold that can fill several tanks from a single connection. In either case, the operation depends on correct grade, compatible equipment, venting, and the correct fill sequence. Pressure refueling also depends on operating pressure limits, refuel-valve operation, and the aircraft’s high-level protection.
Defueling may use a designated connection, aircraft pumps, or other equipment specified for the installation. The destination container and receiving facility matter because drained fuel can be contaminated or of uncertain grade. Heavy-aircraft servicing can also change the distribution of weight enough for tank sequence and aircraft stability to matter.
| Servicing concern | Why it matters |
|---|---|
| Bonding | An electrical connection between the aircraft and fueling equipment reduces the potential difference that can produce a spark |
| Grounding, when prescribed | A connection to earth serves a different function from aircraft-to-equipment bonding. Follow the applicable equipment and facility procedures |
| Correct grade and source | A placard, delivery record, and grade check help prevent a visually plausible misfuel |
| Vent path and high-level protection | Air must escape during filling. Shutoff protection limits overfill in systems designed for it |
| Ignition and spill control | Fuel vapor, electrical equipment, hot surfaces, and spills all affect where and how servicing can safely occur |
| Fuel distribution | The indicated total can be correct while individual tank quantities or left-right balance are outside the intended configuration |
| Post-servicing verification | Tank caps, service connections, quantity indication, and the area around drains and vents provide evidence that servicing ended in the correct condition |